Product Description
Perforated raised floor - Air Flow Panel | ||||||
Type | International Standard | Size (mm) | Concentrated Load (N) | Uniform Load (N) | Ultimate Load (N) | Deflection (mm) |
TLSP-8001 | FS440 | 600*600mm 35-55mm thickness | 1960 | 9720 | 5880 | ≤2 |
TLSP-8002 | FS662 | 2950 | 12500 | 8850 | ≤2 | |
TLSP-8003 | FS800 | 3550 | 16100 | 11250 | ≤2 | |
TLSP-8004 | FS1000 | 4450 | 23000 | 13350 | ≤2 | |
TLSP-8005 | FS1250 | 5560 | 33000 | 16680 | ≤2 | |
TLSP-8006 | FS1500 | 6675 | 34500 | 19892 | ≤2 | |
TLSP-8007 | FS2000 | 8890 | 44450 | 29420 | ≤2 | |
TLSP-8008 | FS2500 | 11110 | 57790 | 37340 | ≤2 | |
TLSP-8009 | FS3000 | 13630 | 68150 | 49890 | ≤2 | |
1. Ventilation Rate available: 0%, 17%, 20%, 22%, 25%, 29%, 35%, 46%, 50%, 55%, 70% etc. 2. Customization is available. 3. Corner lock hole type is available. 4. Epoxy coating. 5. HPL, PVC, SUS304 covering. | ||||||
A tests are performed using CISCA's Recommend Test Procedures for Access Floors with the exception of Design Load
steel perforated panel
Grating Type
steel perforated panel
Tube Welding Type
Open rate 22%
steel perforated panel
Tube Welding Type
Open rate 25%
steel perforated panel
Open rate 29%
steel perforated panel
Tube Welding Type
Open rate 35%
steel perforated panel
Open rate 46
steel perforated panel
Grating Type
Open rate 50%
steel perforated panel
Grating Type
Open rate 55%
steel perforated panel
Grating Type
Open rate 70%
steel perforated panel
Grating Type
● Improved Airflow Management: Air flow raised access flooring allows for effective and controlled airflow management within the data center. The perforations or airflow grates in the panels facilitate the proper distribution of cool air from the HVAC system to the equipment racks, ensuring efficient cooling and preventing hot spots.
● Enhanced Cooling Efficiency: The raised floor design creates an underfloor plenum, providing space for airflow and housing air distribution systems. This setup enables targeted cooling, directing cool air precisely where it is needed, optimizing cooling efficiency, and reducing energy consumption.
● Flexibility and Scalability: Air flow raised access flooring is modular and can be easily reconfigured or expanded to accommodate changes in the data center layout or equipment requirements. It allows for flexibility in arranging the data center space and adapting to future growth and technological advancements.
● Cable Management: The raised floor system conceals and organizes cables, improving cable management. It allows for routing power and data cables neatly beneath the floor, minimizing cable clutter and facilitating easier maintenance and upgrades.
● Reduced Downtime: With proper air flow management and easier maintenance access, the data center can experience reduced downtime during equipment installations, repairs, or upgrades, as these tasks can be performed efficiently and without impacting the live equipment.
Steel Damper
Aluminum Damper